Warning! Refer to the Safety chapters.
Installation
Warning! Read and follow the
instructions carefully. There is a risk of
injury or damage to the appliance.
Make sure that there is no damage to the ap-
pliance from the transportation. Do not con-
nect a damaged appliance. Speak to the
supplier if necessary.
Install built-in appliances only after you as-
semble the appliance into correct built-in
units and work surfaces. Make sure that
built-in units and surfaces obey the stand-
ards.
Obey all orders and standards in force in the
country where you use the appliance (safety
standards, recycling standards, electrical
safety standards etc.)
Warning! Risk of injury from electrical
current.
The electrical mains terminal is live.
Make electrical mains terminal free of volt-
age.
If the fixing bracket is near to the terminal
block, do not let the connection cable come
in contact with the edge of the bracket.
Electrical connection
Make sure that the rated voltage and type of
power on the rating plate agree with the volt-
age and the power of the local power supply.
This appliance is supplied with a mains ca-
ble. It has to be supplied with a correct plug
which can hold the load that the rating plate
rates. Make sure that you install the plug in a
correct socket.
Always use a correctly installed shockproof
socket.
Make sure that there is an access to the
mains plug after the installation.
Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
There is a risk of fire when the appliance is in
connection with an extension cable, an
adapter or a multiple connection. Make sure
that the ground connection agrees with the
standards and regulations.
Do not let the power cable to heat up to a
temperature higher than 90° C.
Make sure that you connect the blue neutral ca-
ble to the terminal with a letter "N" on it. Con-
nect the brown (or black) phase cable to the
terminal which has a letter "L". Keep the phase
cable connected at all times.
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make sure
that the cable section is applicable to the volt-
age and the working temperature. The yellow/
green earth wire must be approximately 2 cm
longer than the brown (or black) phase wire.
Assembly
40-50 mm
55 mm
30 mm
min. 650 mm
490 mm
min. 100 mm
270 mm
B
A
A) seal to remove
B) supplied brackets
Caution! Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.