3. Connect the brown (live) wire to the termi-
nal which is marked with the letter 'L' and is
always connected to the network phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly at-
tached to the outer sheath.
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to the
voltage load and the working temperature. The
yellow/green earth wire (B) must be approxi-
mately 2 cm longer than the live and neutral
wire (A).
AB
Warning! A cut off plug inserted into a 13
amp socket is a serious safety (shock)
hazard. Ensure that the cut off plug is disposed
of safely.
Important! The replacement of electric cable
must be carried out exclusively by the service
force centre or by personnel with similar
competencies, in accordance with the current
regulations.
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make sure
that the cable section is applicable to the volt-
age and the working temperature. The yellow/
green earth wire must be approximately 2 cm
longer than the brown (or black) phase wire.
Building in
40-50 mm
55 mm
30 mm
min. 650 mm
490 mm
min. 100 mm
270 mm
If several 30 cm hobs are to be installed side by
side into the same cut out, an assembly kit in-
cluding a support side bracket and supplemen-
tary seals is available at our Service Centres.
The relevant installation instructions are sup-
plied within the kit package.
R 5mm
min.
55mm
270
+1
mm
490
+1
mm
19
www.zanussi.com